Eland Cables Cable Information (1)

FG7H1OAR Cable

to FG7H1OAR Cable datasheets

FG7H1OAR is a flexible power supply cable used to connect medium voltage equipment, specifically for use in tunnelling and underground mining applications with a voltage rating of 3.6/6kV, 6/10kV or 8.7/15kV, 12/20kV.

FG7H1OAR cable construction

These 3-core Copper cables have individual copper wire braids to offer a protective earthing, and are constructed alongside 3 control conductors. This flexible braided mining cable is suitable for use outdoors. It has an operating temperature of +5oC to +80oC when flexed and -40oC to +80oC when used in a fixed installation.

A low smoke zero halogen (LSZH) verison of this cable is available upon request.

Please refer to  our mining, drilling and tunnelling industry page for our wider mining cable portfolio for equipment and infrastructure, including a range of (N)TSCGECEWÖU cables, (N)3GHSSYCY cables, and our (N)SSCHÖU cable.

FastQuote Logo

Your tailored quote direct to your inbox

Your basket is currently empty

Go back

Construction Table

  FG7H1OAR Cable CS FG7H1OAR - 3.6/6kV and 6/10kV Cable FG7H1OAR Cable CS FG7H1OAR - 8.7/15kV and 12/20kV Cable
VOLTAGE

3.6/6kV, 6/10kV

8.7/15kV, 12/20kV

PHASE CONDUCTOR

Class 5 Flexible Stranded Copper

INSULATION

HEPR (Hard Ethylene Propylene Rubber)

SEMI-CONDUCTIVE LAYERS

Semi-Conductive Tape over the Conductor and Inner and Outer Semi-Conductive Rubber Layer on the Insulation

PROTECTIVE EARTH CONDUCTOR

Individual Copper Wire Braid

CONTROL CONDUCTOR

Class 5 Flexible Stranded Tinned Copper

CENTRAL FILLER

Rubber Compound on a Textile Polyester Support

INNER SHEATH

PVC (Polyvinyl Chloride)

ARMOUR

Steel Wire Braid over the Inner Sheath

OUTER SHEATH

PVC (Polyvinyl Chloride)

YOUR CABLE OPTIONS

Use the FastQuote filters to find the exact cable specifications you need.

Need a bespoke solution? Learn more about customised cables.

Reset

Product name Part No Cores Phase Conductor Size Voltage Rating Sheath colour Length (m)  
FG7H1OAR - 3.6/6kV and 6/10kV CableA7K06KV1025RD3+325mm²3.6/6kVRed
FG7H1OAR - 3.6/6kV and 6/10kV CableA7K06KV1035RD3+335mm²3.6/6kVRed
FG7H1OAR - 3.6/6kV and 6/10kV CableA7K06KV1050RD3+350mm²3.6/6kVRed
FG7H1OAR - 3.6/6kV and 6/10kV CableA7K06KV1070RD3+370mm²3.6/6kVRed
FG7H1OAR - 3.6/6kV and 6/10kV CableA7K06KV1095RD3+395mm²3.6/6kVRed
FG7H1OAR - 3.6/6kV and 6/10kV CableA7K06KV1120RD3+3120mm²3.6/6kVRed
FG7H1OAR - 3.6/6kV and 6/10kV CableA7K06KV1150RD3+3150mm²3.6/6kVRed
FG7H1OAR - 3.6/6kV and 6/10kV CableA7K06KV1185RD3+3185mm²3.6/6kVRed
FG7H1OAR - 3.6/6kV and 6/10kV CableA7K10KV1025RD3+325mm²6/10kVRed
FG7H1OAR - 3.6/6kV and 6/10kV CableA7K10KV1035RD3+335mm²6/10kVRed
FG7H1OAR - 3.6/6kV and 6/10kV CableA7K10KV1050RD3+350mm²6/10kVRed
FG7H1OAR - 3.6/6kV and 6/10kV CableA7K10KV1070RD3+370mm²6/10kVRed
FG7H1OAR - 3.6/6kV and 6/10kV CableA7K10KV1095RD3+395mm²6/10kVRed
FG7H1OAR - 3.6/6kV and 6/10kV CableA7K10KV1120RD3+3120mm²6/10kVRed
FG7H1OAR - 3.6/6kV and 6/10kV CableA7K10KV1150RD3+3150mm²6/10kVRed
FG7H1OAR - 3.6/6kV and 6/10kV CableA7K10KV1185RD3+3185mm²6/10kVRed
FG7H1OAR - 8.7/15kV and 12/20kV CableA7K15KV1025RD3+325mm²8.7/15kVRed
FG7H1OAR - 8.7/15kV and 12/20kV CableA7K15KV1035RD3+335mm²8.7/15kVRed
FG7H1OAR - 8.7/15kV and 12/20kV CableA7K15KV1050RD3+350mm²8.7/15kVRed
FG7H1OAR - 8.7/15kV and 12/20kV CableA7K15KV1070RD3+370mm²8.7/15kVRed
FG7H1OAR - 8.7/15kV and 12/20kV CableA7K15KV1095RD3+395mm²8.7/15kVRed
FG7H1OAR - 8.7/15kV and 12/20kV CableA7K15KV1120RD3+3120mm²8.7/15kVRed
FG7H1OAR - 8.7/15kV and 12/20kV CableA7K15KV1150RD3+3150mm²8.7/15kVRed
FG7H1OAR - 8.7/15kV and 12/20kV CableA7K20KV1025RD3+325mm²12/20kVRed
FG7H1OAR - 8.7/15kV and 12/20kV CableA7K20KV1035RD3+335mm²12/20kVRed
FG7H1OAR - 8.7/15kV and 12/20kV CableA7K20KV1050RD3+350mm²12/20kVRed
FG7H1OAR - 8.7/15kV and 12/20kV CableA7K20KV1070RD3+370mm²12/20kVRed
FG7H1OAR - 8.7/15kV and 12/20kV CableA7K20KV1095RD3+395mm²12/20kVRed
FG7H1OAR - 8.7/15kV and 12/20kV CableA7K20KV1120RD3+3120mm²12/20kVRed