Eland Cables Cable Information (1)

FL2XCY and FLYCY Airfield Cables

to FL2XCY & FLYCY Cable datasheets

The FLYCY cable with it's PVC insulation, and the FL2XCY and FL2XCYRY cables with their XLPE insulation, are used as Medium Voltage power to primary and secondary series circuits in airfield lighting, available in voltages from 2Kv to 10kV. They are provided with a concentric copper wire and copper tape shield. In all three cases, the cables have a robust flame retardant, oil resistant and UV resistant PVC outer sheathing. Given their installation environment it is a key characteristic that these cables are impact and weather resistant.

FL2XCY and FLYCY Airfield Cable Applications

Airfield primary and secondary series circuits can provide power and lighting to runways, taxiways, airport aprons by connecting the Constant Current Regulators and the isolating transformers, and between the isolating transformers themselves. Where additional mechanical protection is required, the FL2XCYRY is recommended with its galvanised steel wire armour.

FL2XCY and FLYCY Airfield Cable Sizes

These single core cables are offered as standard with comparatively small sized copper conductors from 6mm2 to 16mm2- whether solid or stranded in construction. For larger sizes or alternate voltages please contact us for specific weights and dimensions. Additional technical support is available by telephone or email where required for specification and to approach installation challenges. Please also see our range of FAA L-824 approved cables and the Spanish standard RHV and RHZ1 MV cables.

 

 

 

 

FastQuote Logo

Your tailored quote direct to your inbox

Your basket is currently empty

Go back

Construction Table

  CS FL2XCY FL2XCY Airfield Cable CS FL2XCYRY FL2XCYRY Airfield Cable CS FLYCY FLYCY Airfield Cable
VOLTAGE

6/10kV

1/2kV, 1.5/3kV, 2.5/5kV, 3/6kV, 5/10kV

CONDUCTOR

Stranded Copper

Solid or Stranded Copper

INSULATION

XLPE (Cross-linked Polyethylene)

PVC (Polyvinyl Chloride)

SEPARATOR

Tape

SCREEN

Concentric later of copper wires and counter helix of copper tape

Concentric layer of copper wires and counter helix of copper tape

Concentric layer of copper wires and counter helix of tape

INNER SHEATH

PVC (Polyvinyl Chloride)

ARMOUR

GSWA (Galvanised Steel Wire Armour)

OUTER SHEATH

PVC (Polyvinyl Chloride) UV resistant, Oil resistant, Flame retardant

PVC (Polyvinyl Chloride) UV resistant, Oil resistant, Flame retardant

PVC (Polyvinyl Chloride) - UV resistant, Oil resistant, Flame retardant

FL2XCY and FLYCY Airfield Cables

3 product(s)

YOUR CABLE OPTIONS

Use the FastQuote filters to find the exact cable specifications you need.

Need a bespoke solution? Learn more about customised cables.

Reset

Product name Part No Cores Nominal cross-sectional area (mm²) Voltage Rating Sheath colour Length (m)  
FL2XCY Airfield CableF0310KV010060RD16mm²10kVRed
FL2XCYRY Airfield CableF0410KV010060RD16mm²10kVRed
FLYCY Airfield CableF0202KV010060RD16mm²2kVRed
FLYCY Airfield CableF0203KV010060RD16mm²3kVRed
FLYCY Airfield CableF0205KV010060RD16mm²5kVRed
FLYCY Airfield CableF0206KV010060RD16mm²6kVRed
FLYCY Airfield CableF0210KV010060RD16mm²10kVRed