Sub Banner Drum

N2XSH N2XS(F)H & N2XS(FL)H Cables

to N2XSH Cable datasheets

Our Medium Voltage cable portfolio includes the N2SXH Low Smoke Zero Halogen Cable in 10kV, 15kV, 20kV, and 30kV. It is a UV-resistant cable available with optional single and dual waterblocking layers.

N2XSH Cable Applications

N2XSH power distribution cables are used for private grid networks across a wide range of industries including data centres and life sciences new build sites. They are available as either single core or three core variants (where the multicore is referred to as N2XSEH and where the individual cores are screened).

Installation of these unarmoured cables is usually in cable ducts - as three single cores or in triplex formation (3x1) - use of the three-core variant is much less common but is available.

This combination of LSZH insulation and sheathing with constructional layers that are more typically found on the N2XSY PVC and N2XS2Y PE cables gives N2XSH, N2XS(F)H and N2XS(FL)H cables the flexibility to be installed both internally or externally. 

N2XSH Cable Manufacturer Standards

Manufactured generally in accordance with IEC 60502-2, these N2XSH (and N2XSFH / N2XSFLH variants) are flame retardant to IEC/EN 60332-1-2 and low smoke zero halogen to IEC/EN 61034-1/2 and IEC/EN 60754-1/2 making them suitable for internal installations and also UV resistant so they can be used externally too. In practice, this means they can be run from outside to inside in a CPR Compliant installation without the need to joint or change cables at the point of entry.

N2XSFH & N2XSFLH Cable Specification

Installation design and environmental site specifics will determine the cable specification. Where appropriate, additional waterblocking may be required to offer protection against water ingress. Longitudinal waterblocking (the N2XS(F)H cable) and dual longitudinal and radial waterblocking (the N2XS(FL)H cable) can provide such measures.

As before, these cables are usually installed as 3x single cores / triplex, but where the 3-core cable is used it is referred to as N2XSE(F)H and N2XSE(FL)H respectively - with each of the conductors being individually screened.

These cables are commonly installed in cable ducts, providing them with additional mechanical protection. Where the N2XS(F)H and N2XS(FL)H versions are particularly important is in the event the ducts become waterlogged. The single and dual waterblocked layers are commonly a water-swellable tape and an additional water-swellable powder, unless destined for clean environments where powder-free cable construction is stipulated and when two tapes are used. These additional layers prevent any ingress of water from reaching the insulation layer and potentially impeding the performance of the underlying conductor. 

 

N2XSH Cable Voltage Rating

Cable datasheets are provided as standard for N2XSH cables. N2XSH cables are designed with the European market in mind, where fixed installation and direct burial cables can be unarmoured (unlike the BS6622 and BS7835) and they are often for the connection of critical infrastructure and equipment.

Where other voltages are required, please speak to the team and they will be happy to provide the datasheets and information needed.

The N2XSH, N2XS(F)H and N2XS(FL)H is available in 3-core variants at voltage ratings including 6/10kV, 8.7/15kV, 12/20kV and 18/30kV, upon request. 

N2XSH Cable Datasheets

The Eland Cables technical team can support the specification of this multi-purpose cable, advising on the suitability of the N2XSH or a the PVC and PE alternatives as determined by your precise installation environment. For dimensional details and electrical characteristics, please download the datasheet attached.

FastQuote Logo

Your tailored quote direct to your inbox

Your basket is currently empty

Go back

Construction Table

  N2XSY Cable CS N2XSH 12/20kV Cable CS N2XS(F)H N2XS(F)H 12/20kV Cable CS N2XS(FL)H N2XS(FL)H 12/20kV Cable
CONDUCTOR

Class 2 stranded copper

INSULATION

XLPE (Cross-linked Polyethylene)

SCREEN

Copper wires and tape

WATER-BLOCKING
    -

Longitudinal Water-swellable tape either side of the screen

Layer 1 - Longitudinal Water-swellable tape either side of screen Layer 2 - Radial Waterblocking Al/PET bonded to sheath

OUTER SHEATH

LSZH (Low Smoke Zero Halogen)

YOUR CABLE OPTIONS

Use the FastQuote filters to find the exact cable specifications you need.

Need a bespoke solution? Learn more about customised cables.

Reset

Product name Part No Cores Nominal cross-sectional area (mm²) Sheath colour Length (m)  
N2XSH 6/10kV CableA9XH10KV1035RDC135mm²Red
N2XSH 6/10kV CableA9XH10KV1050RDC150mm²Red
N2XSH 6/10kV CableA9XH10KV1070RDC170mm²Red
N2XSH 6/10kV CableA9XH10KV1095RDC195mm²Red
N2XSH 6/10kV CableA9XH10KV1120RDC1120mm²Red
N2XSH 6/10kV CableA9XH10KV1150RDC1150mm²Red
N2XSH 6/10kV CableA9XH10KV1185RDC1185mm²Red
N2XSH 6/10kV CableA9XH10KV1240RDC1240mm²Red
N2XSH 6/10kV CableA9XH10KV1300RDC1300mm²Red
N2XSH 6/10kV CableA9XH10KV1400RDC1400mm²Red
N2XSH 6/10kV CableA9XH10KV1500RDC1500mm²Red
N2XSH 6/10kV CableA9XH10KV1630RDC1630mm²Red
N2XSH 8.7/15kV CableA9XH15KV1035135mm²Black
N2XSH 8.7/15kV CableA9XH15KV1050150mm²Black
N2XSH 8.7/15kV CableA9XH15KV1070170mm²Black
N2XSH 8.7/15kV CableA9XH15KV1095195mm²Black
N2XSH 8.7/15kV CableA9XH15KV11201120mm²Black
N2XSH 8.7/15kV CableA9XH15KV11501150mm²Black
N2XSH 8.7/15kV CableA9XH15KV11851185mm²Black
N2XSH 8.7/15kV CableA9XH15KV12401240mm²Black
N2XSH 8.7/15kV CableA9XH15KV13001300mm²Black
N2XSH 8.7/15kV CableA9XH15KV14001400mm²Black
N2XSH 8.7/15kV CableA9XH15KV15001500mm²Black
N2XSH 8.7/15kV CableA9XH15KV16301630mm²Black
N2XSH 8.7/15kV CableA9XH15KV18001800mm²Black
N2XSH 8.7/15kV CableA9XH15KV1100011000mm²Black
N2XSH 12/20kV CableA9XH20KV1035RDC135mm²Red
N2XSH 12/20kV CableA9XH20KV1050RDC150mm²Red
N2XSH 12/20kV CableA9XH20KV1070RDC170mm²Red
N2XSH 12/20kV CableA9XH20KV1095RDC195mm²Red
N2XSH 12/20kV CableA9XH20KV1120RDC1120mm²Red
N2XSH 12/20kV CableA9XH20KV1150RDC1150mm²Red
N2XSH 12/20kV CableA9XH20KV1185RDC1185mm²Red
N2XSH 12/20kV CableA9XH20KV1240RDC1240mm²Red
N2XSH 12/20kV CableA9XH20KV1300RDC1300mm²Red
N2XSH 12/20kV CableA9XH20KV1400RDC1400mm²Red
N2XSH 12/20kV CableA9XH20KV1500RDC1500mm²Red
N2XSH 12/20kV CableA9XH20KV1630RDC1630mm²Red
N2XSH 18/30kV CableA9XH30KV1035RDC135mm²Red
N2XSH 18/30kV CableA9XH30KV1050RDC150mm²Red
N2XSH 18/30kV CableA9XH30KV1070RDC170mm²Red
N2XSH 18/30kV CableA9XH30KV1095RDC195mm²Red
N2XSH 18/30kV CableA9XH30KV1120RDC1120mm²Red
N2XSH 18/30kV CableA9XH30KV1150RDC1150mm²Red
N2XSH 18/30kV CableA9XH30KV1185RDC1185mm²Red
N2XSH 18/30kV CableA9XH30KV1240RDC1240mm²Red
N2XSH 18/30kV CableA9XH30KV1300RDC1300mm²Red
N2XSH 18/30kV CableA9XH30KV1400RDC1400mm²Red
N2XSH 18/30kV CableA9XH30KV1500RDC1500mm²Red
N2XSH 18/30kV CableA9XH30KV1630RDC1630mm²Red
N2XS(F)H 6/10kV CableA9XHF10KV1035RDC135Red
N2XS(F)H 6/10kV CableA9XHF10KV1050RDC150Red
N2XS(F)H 6/10kV CableA9XHF10KV1070RDC170Red
N2XS(F)H 6/10kV CableA9XHF10KV1095RDC195Red
N2XS(F)H 6/10kV CableA9XHF10KV1120RDC1120Red
N2XS(F)H 6/10kV CableA9XHF10KV1150RDC1150Red
N2XS(F)H 6/10kV CableA9XHF10KV1185RDC1185Red
N2XS(F)H 6/10kV CableA9XHF10KV1240RDC1240Red
N2XS(F)H 6/10kV CableA9XHF10KV1300RDC1300Red
N2XS(F)H 6/10kV CableA9XHF10KV1400RDC1400Red
N2XS(F)H 6/10kV CableA9XHF10KV1500RDC1500Red
N2XS(F)H 6/10kV CableA9XHF10KV1630RDC1630Red
N2XS(F)H 8.7/15kV CableA9XHF15KV1035135mm²Black
N2XS(F)H 8.7/15kV CableA9XHF15KV1050150mm²Black
N2XS(F)H 8.7/15kV CableA9XHF15KV1070170mm²Black
N2XS(F)H 8.7/15kV CableA9XHF15KV1095195mm²Black
N2XS(F)H 8.7/15kV CableA9XHF15KV11201120mm²Black
N2XS(F)H 8.7/15kV CableA9XHF15KV11501150mm²Black
N2XS(F)H 8.7/15kV CableA9XHF15KV11851185mm²Black
N2XS(F)H 8.7/15kV CableA9XHF15KV12401240mm²Black
N2XS(F)H 8.7/15kV CableA9XHF15KV13001300mm²Black
N2XS(F)H 8.7/15kV CableA9XHF15KV14001400mm²Black
N2XS(F)H 8.7/15kV CableA9XHF15KV15001500mm²Black
N2XS(F)H 8.7/15kV CableA9XHF15KV16301630mm²Black
N2XS(F)H 8.7/15kV CableA9XHF15KV18001800mm²Black
N2XS(F)H 8.7/15kV CableA9XHF15KV1100011000mm²Black
N2XS(F)H 12/20kV CableA9XHF20KV1035RDC135mm²Red
N2XS(F)H 12/20kV CableA9XHF20KV1050RDC150mm²Red
N2XS(F)H 12/20kV CableA9XHF20KV1070RDC170mm²Red
N2XS(F)H 12/20kV CableA9XHF20KV1095RDC195mm²Red
N2XS(F)H 12/20kV CableA9XHF20KV1120RDC1120mm²Red
N2XS(F)H 12/20kV CableA9XHF20KV1150RDC1150mm²Red
N2XS(F)H 12/20kV CableA9XHF20KV1185RDC1185mm²Red
N2XS(F)H 12/20kV CableA9XHF20KV1240RDC1240mm²Red
N2XS(F)H 12/20kV CableA9XHF20KV1300RDC1300mm²Red
N2XS(F)H 12/20kV CableA9XHF20KV1400RDC1400mm²Red
N2XS(F)H 12/20kV CableA9XHF20KV1500RDC1500mm²Red
N2XS(F)H 12/20kV CableA9XHF20KV1630RDC1630mm²Red
N2XS(F)H 12/20kV CableA9XHF20KV3035RDC335mm²Red
N2XS(F)H 12/20kV CableA9XHF20KV3050RDC350mm²Red
N2XS(F)H 12/20kV CableA9XHF20KV3070RDC370mm²Red
N2XS(F)H 12/20kV CableA9XHF20KV3095RDC395mm²Red
N2XS(F)H 12/20kV CableA9XHF20KV3120RDC3120mm²Red
N2XS(F)H 12/20kV CableA9XHF20KV3150RDC3150mm²Red
N2XS(F)H 12/20kV CableA9XHF20KV3185RDC3185mm²Red
N2XS(F)H 12/20kV CableA9XHF20KV3240RDC3240mm²Red
N2XS(F)H 12/20kV CableA9XHF20KV3300RDC3300mm²Red
N2XS(F)H 12/20kV CableA9XHF20KV3400RDC3400mm²Red
N2XS(F)H 18/30kVA9XHF30KV1035RDC135mm²Red
N2XS(F)H 18/30kVA9XHF30KV1050RDC150mm²Red
N2XS(F)H 18/30kVA9XHF30KV1070RDC170mm²Red
N2XS(F)H 18/30kVA9XHF30KV1095RDC195mm²Red
N2XS(F)H 18/30kVA9XHF30KV1120RDC1120mm²Red
N2XS(F)H 18/30kVA9XHF30KV1150RDC1150mm²Red
N2XS(F)H 18/30kVA9XHF30KV1185RDC1185mm²Red
N2XS(F)H 18/30kVA9XHF30KV1240RDC1240mm²Red
N2XS(F)H 18/30kVA9XHF30KV1300RDC1300mm²Red
N2XS(F)H 18/30kVA9XHF30KV1400RDC1400mm²Red
N2XS(F)H 18/30kVA9XHF30KV1500RDC1500mm²Red
N2XS(F)H 18/30kVA9XHF30KV1630RDC1630mm²Red
N2XS(FL)H 6/10kV CableA9XHL10KV1035RDC135mm²Red
N2XS(FL)H 6/10kV CableA9XHL10KV1050RDC150mm²Red
N2XS(FL)H 6/10kV CableA9XHL10KV1070RDC170mm²Red
N2XS(FL)H 6/10kV CableA9XHL10KV1095RDC195mm²Red
N2XS(FL)H 6/10kV CableA9XHL10KV1120RDC1120mm²Red
N2XS(FL)H 6/10kV CableA9XHL10KV1150RDC1150mm²Red
N2XS(FL)H 6/10kV CableA9XHL10KV1185RDC1185mm²Red
N2XS(FL)H 6/10kV CableA9XHL10KV1240RDC1240mm²Red
N2XS(FL)H 6/10kV CableA9XHL10KV1300RDC1300mm²Red
N2XS(FL)H 6/10kV CableA9XHL10KV1400RDC1400mm²Red
N2XS(FL)H 6/10kV CableA9XHL10KV1500RDC1500mm²Red
N2XS(FL)H 6/10kV CableA9XHL10KV1630RDC1630mm²Red
N2XS(FL)H 12/20kV CableA9XHL20KV1035RDC135mm²Red
N2XS(FL)H 12/20kV CableA9XHL20KV1050RDC150mm²Red
N2XS(FL)H 12/20kV CableA9XHL20KV1070RDC170mm²Red
N2XS(FL)H 12/20kV CableA9XHL20KV1095RDC195mm²Red
N2XS(FL)H 12/20kV CableA9XHL20KV1120RDC1120mm²Red
N2XS(FL)H 12/20kV CableA9XHL20KV1150RDC1150mm²Red
N2XS(FL)H 12/20kV CableA9XHL20KV1185RDC1185mm²Red
N2XS(FL)H 12/20kV CableA9XHL20KV1240RDC1240mm²Red
N2XS(FL)H 12/20kV CableA9XHL20KV1300RDC1300mm²Red
N2XS(FL)H 12/20kV CableA9XHL20KV1400RDC1400mm²Red
N2XS(FL)H 12/20kV CableA9XHL20KV1500RDC1500mm²Red
N2XS(FL)H 12/20kV CableA9XHL20KV1630RDC1630mm²Red
N2XS(FL)H 18/30kV CableA9XHL30KV1035RDC135mm²Red
N2XS(FL)H 18/30kV CableA9XHL30KV1050RDC150mm²Red
N2XS(FL)H 18/30kV CableA9XHL30KV1070RDC170mm²Red
N2XS(FL)H 18/30kV CableA9XHL30KV1095RDC195mm²Red
N2XS(FL)H 18/30kV CableA9XHL30KV1120RDC1120mm²Red
N2XS(FL)H 18/30kV CableA9XHL30KV1150RDC1150mm²Red
N2XS(FL)H 18/30kV CableA9XHL30KV1185RDC1185mm²Red
N2XS(FL)H 18/30kV CableA9XHL30KV1240RDC1240mm²Red
N2XS(FL)H 18/30kV CableA9XHL30KV1300RDC1300mm²Red
N2XS(FL)H 18/30kV CableA9XHL30KV1400RDC1400mm²Red
N2XS(FL)H 18/30kV CableA9XHL30KV1500RDC1500mm²Red
N2XS(FL)H 18/30kV CableA9XHL30KV1630RDC1630mm²Red