Eland Cables Cable Information (1)

(N)3GHSSYCY Cables

to (N)3GHSSYCY Cable datasheets

Our (N)3GHSSYCY is a flexible energy supply cable designed to supply power to medium voltage (MV) equipment. This range is manufactured in accordance with VDE0250 standard and it is designed to operate effectively in tunnelling and underground mining applications. This cable is designed with optimised insulation wall thickness and optimised outer diameter. It also allows effective monitoring of outer damage an invaluable property given the hazardous environments in which this cable tends to operate.

The (N)3GHSSYCY is available with a Voltage Rating of 3.6/6kv, 6/10kV or 8.7/15kV, 12/20kV. They operate in ambient temperatures of -40oC to +80oC when fixed and +5oC to +80oC when flexed.

Technical support for (N)3GHSSYCY and other mining cables

As a leading supplier of cables for the mining industry across infrastructure and mining applications, Eland Cables' technical team has a wealth of experience advising on opencast mining cable selection and applications for enclosed spaces. Please contact us to discuss your specific technical and logistical requirements.

FastQuote Logo

Your tailored quote direct to your inbox

Your basket is currently empty

Go back

Construction Table

  N3GHSSYCY Cable CS (N)3GHSSYCY - 3.6/6kV and 6/10kV Cable N3GHSSYCY Cable CS (N)3GHSSYCY - 8.7/15kV and 12/20kV Cable
VOLTAGE

3.6/6kV & 6/10kV

8.7/15kV & 12/20kV

PHASE CONDUCTOR

Class 5 Flexible Stranded Copper

INSULATION

Rubber Compound

SEMI-CONDUCTIVE LAYERS

Semi-Conductive Tape over the Conductor and Inner and Outer Semi-Conductive Rubber Layer on the Insulation

PROTECTIVE EARTH CONDUCTOR

Individual Copper Wire Screen

CONTROL CONDUCTOR

Class 5 Flexible Stranded Tinned Copper

CENTRAL FILLER

Rubber Compound on a Textile Polyester Support

INNER SHEATH

PVC (Polyvinyl Chloride)

MONITORING CONDUCTOR

Copper Wire

INNER SHEATH 2

PVC (Polyvinyl Chloride)

ARMOUR

Steel Wire Braid over the Second Inner Sheath

OUTER SHEATH

PVC (Polyvinyl Chloride)

YOUR CABLE OPTIONS

Use the FastQuote filters to find the exact cable specifications you need.

Need a bespoke solution? Learn more about customised cables.

Reset

Product name Part No Cores Nominal cross-sectional area (mm²) Phase Conductor Size Voltage Rating Sheath colour Length (m)  
(N)3GHSSYCY - 3.6/6kV and 6/10kV CableA7F06KV1025RD3+3+3+UL25mm²253.6/6kVRed
(N)3GHSSYCY - 3.6/6kV and 6/10kV CableA7F06KV1035RD3+3+3+UL35mm²353.6/6kVRed
(N)3GHSSYCY - 3.6/6kV and 6/10kV CableA7F06KV1050RD3+3+3+UL50mm²503.6/6kVRed
(N)3GHSSYCY - 3.6/6kV and 6/10kV CableA7F06KV1070RD3+3+3+UL70mm²703.6/6kVRed
(N)3GHSSYCY - 3.6/6kV and 6/10kV CableA7F06KV1095RD3+3+3+UL95mm²953.6/6kVRed
(N)3GHSSYCY - 3.6/6kV and 6/10kV CableA7F06KV1120RD3+3+3+UL120mm²1203.6/6kVRed
(N)3GHSSYCY - 3.6/6kV and 6/10kV CableA7F06KV1150RD3+3+3+UL150mm²1503.6/6kVRed
(N)3GHSSYCY - 3.6/6kV and 6/10kV CableA7F10KV1025RD3+3+3+UL25mm²256/10kVRed
(N)3GHSSYCY - 3.6/6kV and 6/10kV CableA7F10KV1035RD3+3+3+UL35mm²356/10kVRed
(N)3GHSSYCY - 3.6/6kV and 6/10kV CableA7F10KV1050RD3+3+3+UL50mm²506/10kVRed
(N)3GHSSYCY - 3.6/6kV and 6/10kV CableA7F10KV1070RD3+3+3+UL70mm²706/10kVRed
(N)3GHSSYCY - 3.6/6kV and 6/10kV CableA7F10KV1095RD3+3+3+UL95mm²956/10kVRed
(N)3GHSSYCY - 3.6/6kV and 6/10kV CableA7F10KV1120RD3+3+3+UL120mm²1206/10kVRed
(N)3GHSSYCY - 3.6/6kV and 6/10kV CableA7F10KV1150RD3+3+3+UL150mm²1506/10kVRed
(N)3GHSSYCY - 8.7/15kV and 12/20kV CableA7F15KV1025RD3+3+3+ULn/a258.7/15kVRed
(N)3GHSSYCY - 8.7/15kV and 12/20kV CableA7F15KV1035RD3+3+3+ULn/a358.7/15kVRed
(N)3GHSSYCY - 8.7/15kV and 12/20kV CableA7F15KV1050RD3+3+3+ULn/a508.7/15kVRed
(N)3GHSSYCY - 8.7/15kV and 12/20kV CableA7F15KV1070RD3+3+3+ULn/a708.7/15kVRed
(N)3GHSSYCY - 8.7/15kV and 12/20kV CableA7F15KV1095RD3+3+3+ULn/a958.7/15kVRed
(N)3GHSSYCY - 8.7/15kV and 12/20kV CableA7F15KV1120RD3+3+3+ULn/a1208.7/15kVRed
(N)3GHSSYCY - 8.7/15kV and 12/20kV CableA7F20KV1025RD3+3+3+ULn/a2512/20kVRed
(N)3GHSSYCY - 8.7/15kV and 12/20kV CableA7F20KV1035RD3+3+3+ULn/a3512/20kVRed
(N)3GHSSYCY - 8.7/15kV and 12/20kV CableA7F20KV1050RD3+3+3+ULn/a5012/20kVRed
(N)3GHSSYCY - 8.7/15kV and 12/20kV CableA7F20KV1070RD3+3+3+ULn/a7012/20kVRed
(N)3GHSSYCY - 8.7/15kV and 12/20kV CableA7F20KV1095RD3+3+3+ULn/a9512/20kVRed
(N)3GHSSYCY - 8.7/15kV and 12/20kV CableA7F20KV1120RD3+3+3+ULn/a12012/20kVRed