The NA2X2Y Aluminium conductor low voltage cables are for power distribution applications and can be applicable to most industries across EMEA. Manufactured in accordance with International standard IEC 60502-1, these versatile AL-XLPE-MDPE cables with a rated voltage of 0.6/1kV or 1.8/3kV are commonly specified in renewablebattery storage, and clean energy projects, as well as e-Mobility infrastructure installations.

NA2X2Y Cable specification

The choice of aluminium conductors makes them significantly more lightweight than copper conductor cables offering a comparable current carrying capacity; but this should be considered alongside the increased overall diameter of aluminium vs copper. External installations without space constraints, may choose to specify the AL-XLPE-MDPE NA2X2Y cables.

The choice of outer sheathing in Medium Density Polyethylene (MDPE) provides a robust, tear and abrasion resistant protection against the physical environment. The inclusion of Cross-Linked Polyethylene (XLPE) insulation adds to their suitability, allowing for a maximum conductor operating temperature of +90oC.

The construction and electrical characteristics for both the NA2X2Y 1kV and NA2X2Y 3kV cable are provided on the technical datasheets below.

 

 

For NA2XY cables with PVC sheathing, or the NA2XH cables with LSZH sheathing, please see the respective datasheets linked on the cable pages. Copper conductor cables  - N2X2Y cable (MDPE), N2XY cable (PVC) and N2XH cable (LSZH) are all similarly available - the latter also with a Class 5 flexible variant to support more challenging routing on internal installations.

For support with specification, further information, or to receive a quotation, please contact the team.

 

FastQuote Logo

Your tailored quote direct to your inbox

Your basket is currently empty

Go back

NA2X2Y Cables

2 product(s)

YOUR CABLE OPTIONS

Use the FastQuote filters to find the exact cable specifications you need.

Need a bespoke solution? Learn more about customised cables.

Reset

Product name Part No Cores Nominal cross-sectional area (mm²) Sheath colour Length (m)  
NA2X2Y Cable 0.6/1kVA9O2Y01016116Black
NA2X2Y Cable 0.6/1kVA9O2Y01025125Black
NA2X2Y Cable 0.6/1kVA9O2Y01035135Black
NA2X2Y Cable 0.6/1kVA9O2Y01050150Black
NA2X2Y Cable 0.6/1kVA9O2Y01070170Black
NA2X2Y Cable 0.6/1kVA9O2Y01095195Black
NA2X2Y Cable 0.6/1kVA9O2Y011201120Black
NA2X2Y Cable 0.6/1kVA9O2Y011501150Black
NA2X2Y Cable 0.6/1kVA9O2Y011851185Black
NA2X2Y Cable 0.6/1kVA9O2Y012401240Black
NA2X2Y Cable 0.6/1kVA9O2Y013001300Black
NA2X2Y Cable 0.6/1kVA9O2Y014001400Black
NA2X2Y Cable 0.6/1kVA9O2Y015001500Black
NA2X2Y Cable 0.6/1kVA9O2Y016301630Black
NA2X2Y Cable 0.6/1kVA9O2Y018001800Black
NA2X2Y Cable 0.6/1kVA9O2Y01100011000Black
NA2X2Y Cable 1.8-3kVA9O2Y3KV01016116Black
NA2X2Y Cable 1.8-3kVA9O2Y3KV01025125Black
NA2X2Y Cable 1.8-3kVA9O2Y3KV01035135Black
NA2X2Y Cable 1.8-3kVA9O2Y3KV01050150Black
NA2X2Y Cable 1.8-3kVA9O2Y3KV01070170Black
NA2X2Y Cable 1.8-3kVA9O2Y3KV01095195Black
NA2X2Y Cable 1.8-3kVA9O2Y3KV011201120Black
NA2X2Y Cable 1.8-3kVA9O2Y3KV011501150Black
NA2X2Y Cable 1.8-3kVA9O2Y3KV011851185Black
NA2X2Y Cable 1.8-3kVA9O2Y3KV012401240Black
NA2X2Y Cable 1.8-3kVA9O2Y3KV013001300Black
NA2X2Y Cable 1.8-3kVA9O2Y3KV014001400Black
NA2X2Y Cable 1.8-3kVA9O2Y3KV015001500Black
NA2X2Y Cable 1.8-3kVA9O2Y3KV016301630Black
NA2X2Y Cable 1.8-3kVA9O2Y3KV018001800Black
NA2X2Y Cable 1.8-3kVA9O2Y3KV01100011000Black