NYFGBY Cable
Eland Cables' portfolio of European standard low voltage power cables includes the armoured NYFGbY cable. This 0.6/1kV cable is manufactured in accordance with IEC 60502-1 and DIN VDE 0276-603, for use in fixed installation in power networks across Europe.
NYFGbY Cable Specification
With mechanical protection from galvanised steel flat wires and galvanised steel tape, the combination of steel wires and tape allow for applications subject to higher tensile stresses during installation or operation. They also provide an effective barrier to rodent attack.
With its steel wire armour the NYFGbY cable is suitable for direct burial - the flat wires (as compared to standard SWA round wires) create a marginally smaller overall cable diameter so may be considered where space constraints exist.
The flame retardant, UV resistant, black PVC outer sheath means it is also suitable for external installations including in sealed ducts.
The NYFGbY cable has a maximum operating temperature of 70oC and is available with coloured cores in accordance with DIN VDE 0292.
More information
NYFGbY Power Cable Technical Support and Datasheets
Depending on the installation, the surrounding environment, and the building regulations governing the project, it may be determined that the NYFGbY is the most appropriate cable. Where you are unsure or require technical support with determining this, our team is available to assist your calculations. It should be noted that the N2XFGbY cable with XLPE insulation instead of PVC offers a maximum operating temperature of 90oC and may be more appropriate. The attached datasheets provide key cable sizing and electrical characteristics for cable selection, but should additional sizes be required, again, our team are able to assist.
YOUR CABLE OPTIONS
Use the FastQuote filters to find the exact cable specifications you need.
Need a bespoke solution? Learn more about customised cables.
Product name | Part No | Cores | Nominal cross-sectional area (mm²) | Sheath colour | Length (m) | |
---|---|---|---|---|---|---|
NYFGBY Cable | B2H05010BK | 3 | 16mm² | Black | ||
NYFGBY Cable | B2H05016BK | 3 | 25mm² | Black | ||
NYFGBY Cable | B2H05025BK | 3 | 35mm² | Black | ||
NYFGBY Cable | B2H05035BK | 3 | 50mm² | Black | ||
NYFGBY Cable | B2H05050BK | 3 | 70mm² | Black | ||
NYFGBY Cable | B2J03095BK | 3 | 95mm² | Black | ||
NYFGBY Cable | B2J03120BK | 3 | 120mm² | Black | ||
NYFGBY Cable | B2J03150BK | 3 | 150mm² | Black | ||
NYFGBY Cable | B2J03185BK | 3 | 185mm² | Black | ||
NYFGBY Cable | B2J03240BK | 3 | 240mm² | Black | ||
NYFGBY Cable | B2J0316/10BK | 3 | 16/10mm² | Black | ||
NYFGBY Cable | B2J03025/16BK | 3 | 25/16mm² | Black | ||
NYFGBY Cable | B2J03035/16BK | 3 | 35/16mm² | Black | ||
NYFGBY Cable | B2J03050/25BK | 3 | 50/25mm² | Black | ||
NYFGBY Cable | B2J03070/35BK | 3 | 70/35mm² | Black | ||
NYFGBY Cable | B2J03095/50BK | 3 | 95/50mm² | Black | ||
NYFGBY Cable | B2J03120/70BK | 3 | 120/70mm² | Black | ||
NYFGBY Cable | B2J03150/70BK | 3 | 150/70mm² | Black | ||
NYFGBY Cable | B2J03185/95BK | 3 | 185/95mm² | Black | ||
NYFGBY Cable | B2J03240/120BK | 3 | 240/120mm² | Black | ||
NYFGBY Cable | B2J04010BK | 4 | 10mm² | Black | ||
NYFGBY Cable | B2J04016BK | 4 | 16mm² | Black | ||
NYFGBY Cable | B2J04025BK | 4 | 25mm² | Black | ||
NYFGBY Cable | B2J04035BK | 4 | 35mm² | Black | ||
NYFGBY Cable | B2J04050BK | 4 | 50mm² | Black | ||
NYFGBY Cable | B2J04070BK | 4 | 70mm² | Black | ||
NYFGBY Cable | B2J04095BK | 4 | 95mm² | Black | ||
NYFGBY Cable | B2J04120BK | 4 | 120mm² | Black | ||
NYFGBY Cable | B2J04150BK | 4 | 150mm² | Black | ||
NYFGBY Cable | B2J04185BK | 4 | 185mm² | Black | ||
NYFGBY Cable | B2J04240BK | 4 | 240mm² | Black | ||
NYFGBY Cable | B2J04300BK | 4 | 300mm² | Black | ||
NYFGBY Cable | B2J05010BK | 5 | 10mm² | Black | ||
NYFGBY Cable | B2J05016BK | 5 | 16mm² | Black | ||
NYFGBY Cable | B2J05025BK | 5 | 25mm² | Black | ||
NYFGBY Cable | B2J05035BK | 5 | 35mm² | Black | ||
NYFGBY Cable | B2J05050BK | 5 | 50mm² | Black |