YMz1Krvasdlwd-AL Cables
to YMz1Krvasdlwd-AL Cable datasheets
Our range of Medium Voltage cables includes the YMz1Krvasdlwd-AL. They are the aluminium conductor equivalent of the YMz1Krvasdlwd cables. These single core and 3-core cables are manufactured in general accordance with HD 620-10J and NEN3620 for the Dutch market and the wider European power distribution market.
Medium voltage cables like the YMz1Krvasdlwd-AL are essential to infrastructure projects, connecting grid and sub-station to transformers.
YMz1Krvasdlwd-AL Cable Voltages & Specification
YMz1Krvasdlwd-AL cables are available with rated voltages of 8.7/15kV, 12/20kV and 18/30kV, in core cross-sectional sizes ranging from 50mm2 to 240mm2 as standard.
The YMz1Krvasdlwd-AL offer a Low Smoke Zero Halogen (LSZH) UV resistant sheathing, with underlying waterblocking properties. The UV resistance sheathing makes the cable suitable for external exposed installation, whilst the radial and longitudinal waterblocking measures prevent water ingress affecting the underlying insulation and conductor. This makes the YMz1Krvasdlwd-Al cable suitable for grid networks buried directly or in cable ducts.
They are suitable for an operating temperature range of 0oC to +90oC (ambient temperature 20oC).
YMz1Krvasdlwd-Al Datasheets and Technical Support
The attached technical datasheets provide key dimensional and electrical data to support cable selection. Where additional information is required, please speak to the team who will be able to assist.
For support on specification of YMz1Krvasdlwd-AL cables, other geo-specific European standard cables, or MV cables with a wider operating temperature range, please speak to our sales team and MV experts who will be happy to help.
Our medium voltage cables, including the YMz1Krvasdlwd-AL in all voltages, are subject to rigorous testing in The Cable Lab’s specialist MV facility. With quality and compliance of utmost importance in cables with higher voltages, where even microscopic faults can have an impact on the performance of the cables, the impartial analysis we undertake on all drums prior to despatch gives customers the confidence to install these cables at the initial stages of a project build, safe in the knowledge that they will deliver the expected performance at the time of commissioning.
YMz1Krvasdlwd-AL Cables
YOUR CABLE OPTIONS
Use the FastQuote filters to find the exact cable specifications you need.
Need a bespoke solution? Learn more about customised cables.
Product name | Part No | Cores | Nominal cross-sectional area (mm²) | Sheath colour | Length (m) | |
---|---|---|---|---|---|---|
YMz1Krvasdlwd-AL 8.7/15kV | B1E15KV01050RD | 1 | 50mm² | Red | ||
YMz1Krvasdlwd-AL 8.7/15kV | B1E15KV01070RD | 1 | 70mm² | Red | ||
YMz1Krvasdlwd-AL 8.7/15kV | B1E15KV01095RD | 1 | 95mm² | Red | ||
YMz1Krvasdlwd-AL 8.7/15kV | B1E15KV01120RD | 1 | 120mm² | Red | ||
YMz1Krvasdlwd-AL 8.7/15kV | B1E15KV01150RD | 1 | 150mm² | Red | ||
YMz1Krvasdlwd-AL 8.7/15kV | B1E15KV01185RD | 1 | 185mm² | Red | ||
YMz1Krvasdlwd-AL 8.7/15kV | B1E15KV01240RD | 1 | 240mm² | Red | ||
YMz1Krvasdlwd-AL 8.7/15kV | B1E15KV01300RD | 1 | 300mm² | Red | ||
YMz1Krvasdlwd-AL 8.7/15kV | B1E15KV01400RD | 1 | 400mm² | Red | ||
YMz1Krvasdlwd-AL 8.7/15kV | B1E15KV01500RD | 1 | 500mm² | Red | ||
YMz1Krvasdlwd-AL 8.7/15kV | B1E15KV01630RD | 1 | 630mm² | Red | ||
YMz1Krvasdlwd-AL 8.7/15kV | B1E15KV03050RD | 3 | 50mm² | Red | ||
YMz1Krvasdlwd-AL 8.7/15kV | B1E15KV03070RD | 3 | 70mm² | Red | ||
YMz1Krvasdlwd-AL 8.7/15kV | B1E15KV03095RD | 3 | 95mm² | Red | ||
YMz1Krvasdlwd-AL 8.7/15kV | B1E15KV03120RD | 3 | 120mm² | Red | ||
YMz1Krvasdlwd-AL 8.7/15kV | B1E15KV03150RD | 3 | 150mm² | Red | ||
YMz1Krvasdlwd-AL 8.7/15kV | B1E15KV03185RD | 3 | 185mm² | Red | ||
YMz1Krvasdlwd-AL 8.7/15kV | B1E15KV03240RD | 3 | 240mm² | Red | ||
YMz1Krvasdlwd-AL 8.7/15kV | B1E15KV03300RD | 3 | 300mm² | Red | ||
YMz1Krvasdlwd-AL 12/20kV | B1E20KV01050RD | 1 | 50mm² | Red | ||
YMz1Krvasdlwd-AL 12/20kV | B1E20KV01070RD | 1 | 70mm² | Red | ||
YMz1Krvasdlwd-AL 12/20kV | B1E20KV01095RD | 1 | 95mm² | Red | ||
YMz1Krvasdlwd-AL 12/20kV | B1E20KV01120RD | 1 | 120mm² | Red | ||
YMz1Krvasdlwd-AL 12/20kV | B1E20KV01150RD | 1 | 150mm² | Red | ||
YMz1Krvasdlwd-AL 12/20kV | B1E20KV01185RD | 1 | 185mm² | Red | ||
YMz1Krvasdlwd-AL 12/20kV | B1E20KV01240RD | 1 | 240mm² | Red | ||
YMz1Krvasdlwd-AL 12/20kV | B1E20KV01300RD | 1 | 300mm² | Red | ||
YMz1Krvasdlwd-AL 12/20kV | B1E20KV01400RD | 1 | 400mm² | Red | ||
YMz1Krvasdlwd-AL 12/20kV | B1E20KV01500RD | 1 | 500mm² | Red | ||
YMz1Krvasdlwd-AL 12/20kV | B1E20KV01630RD | 1 | 630mm² | Red | ||
YMz1Krvasdlwd-AL 12/20kV | B1E20KV03050RD | 3 | 50mm² | Red | ||
YMz1Krvasdlwd-AL 12/20kV | B1E20KV03070RD | 3 | 70mm² | Red | ||
YMz1Krvasdlwd-AL 12/20kV | B1E20KV03095RD | 3 | 95mm² | Red | ||
YMz1Krvasdlwd-AL 12/20kV | B1E20KV03120RD | 3 | 120mm² | Red | ||
YMz1Krvasdlwd-AL 12/20kV | B1E20KV03150RD | 3 | 150mm² | Red | ||
YMz1Krvasdlwd-AL 12/20kV | B1E20KV03185RD | 3 | 185mm² | Red | ||
YMz1Krvasdlwd-AL 12/20kV | B1E20KV03240RD | 3 | 240mm² | Red | ||
YMz1Krvasdlwd-AL 18/30kV | B1E30KV01050RD | 1 | 50mm² | Red | ||
YMz1Krvasdlwd-AL 18/30kV | B1E30KV01070RD | 1 | 70mm² | Red | ||
YMz1Krvasdlwd-AL 18/30kV | B1E30KV01095RD | 1 | 95mm² | Red | ||
YMz1Krvasdlwd-AL 18/30kV | B1E30KV01120RD | 1 | 120mm² | Red | ||
YMz1Krvasdlwd-AL 18/30kV | B1E30KV01150RD | 1 | 150mm² | Red | ||
YMz1Krvasdlwd-AL 18/30kV | B1E30KV01185RD | 1 | 185mm² | Red | ||
YMz1Krvasdlwd-AL 18/30kV | B1E30KV01240RD | 1 | 240mm² | Red | ||
YMz1Krvasdlwd-AL 18/30kV | B1E30KV01300RD | 1 | 300mm² | Red | ||
YMz1Krvasdlwd-AL 18/30kV | B1E30KV01400RD | 1 | 400mm² | Red | ||
YMz1Krvasdlwd-AL 18/30kV | B1E30KV01500RD | 1 | 500mm² | Red | ||
YMz1Krvasdlwd-AL 18/30kV | B1E30KV01630RD | 1 | 630mm² | Red | ||
YMz1Krvasdlwd-AL 18/30kV | B1E30KV03050RD | 3 | 50mm² | Red | ||
YMz1Krvasdlwd-AL 18/30kV | B1E30KV03070RD | 3 | 70mm² | Red | ||
YMz1Krvasdlwd-AL 18/30kV | B1E30KV03095RD | 3 | 95mm² | Red | ||
YMz1Krvasdlwd-AL 18/30kV | B1E30KV03120RD | 3 | 120mm² | Red | ||
YMz1Krvasdlwd-AL 18/30kV | B1E30KV03150RD | 3 | 150mm² | Red |