Eland Cables Cable Information (1)

YMz1Krvasdlwd-AL Cables

to YMz1Krvasdlwd-AL Cable datasheets

Our range of Medium Voltage cables includes the YMz1Krvasdlwd-AL. They are the aluminium conductor equivalent of the YMz1Krvasdlwd cables. These single core and 3-core cables are manufactured in general accordance with HD 620-10J and NEN3620 for the Dutch market and the wider European power distribution market.

Medium voltage cables like the YMz1Krvasdlwd-AL are essential to infrastructure projects, connecting grid and sub-station to transformers. 

YMz1Krvasdlwd-AL Cable Voltages & Specification

YMz1Krvasdlwd-AL cables are available with rated voltages of 8.7/15kV, 12/20kV and 18/30kV, in core cross-sectional sizes ranging from 50mm2 to 240mm2 as standard.

The YMz1Krvasdlwd-AL offer a Low Smoke Zero Halogen (LSZH) UV resistant sheathing, with underlying waterblocking properties. The UV resistance sheathing makes the cable suitable for external exposed installation, whilst the radial and longitudinal waterblocking measures prevent water ingress affecting the underlying insulation and conductor. This makes the YMz1Krvasdlwd-Al cable suitable for grid networks buried directly or in cable ducts. 

They are suitable for an operating temperature range of 0oC to +90oC (ambient temperature 20oC).

YMz1Krvasdlwd-Al Datasheets and Technical Support

The attached technical datasheets provide key dimensional and electrical data to support cable selection. Where additional information is required, please speak to the team who will be able to assist.

For support on specification of YMz1Krvasdlwd-AL cables, other geo-specific European standard cables, or MV cables with a wider operating temperature range, please speak to our sales team and MV experts who will be happy to help.

Our medium voltage cables, including the YMz1Krvasdlwd-AL in all voltages, are subject to rigorous testing in The Cable Lab’s specialist MV facility. With quality and compliance of utmost importance in cables with higher voltages, where even microscopic faults can have an impact on the performance of the cables, the impartial analysis we undertake on all drums prior to despatch gives customers the confidence to install these cables at the initial stages of a project build, safe in the knowledge that they will deliver the expected performance at the time of commissioning.

FastQuote Logo

Your tailored quote direct to your inbox

Your basket is currently empty

Go back

Construction Table

  Ymz1krvasdlwd-Al Aluminium Cable CS YMz1Krvasdlwd-AL 8.7/15kV Ymz1krvasdlwd-Al Aluminium Cable CS YMz1Krvasdlwd-AL 12/20kV Ymz1krvasdlwd-Al Aluminium Cable CS YMz1Krvasdlwd-AL 18/30kV
VOLTAGE

8.7/15kV

12/20kV

18/30kV

CONDUCTOR

Class 2 stranded Aluminium

INSULATION

XLPE (Cross-linked Polyethylene)

SCREEN

Copper wires and Tape

TAPE

Radial and Longitudinal Waterblocking Tape

OUTER SHEATH

LSZH (Low Smoke Zero Halogen)

YOUR CABLE OPTIONS

Use the FastQuote filters to find the exact cable specifications you need.

Need a bespoke solution? Learn more about customised cables.

Reset

Product name Part No Cores Nominal cross-sectional area (mm²) Sheath colour Length (m)  
YMz1Krvasdlwd-AL 8.7/15kVB1E15KV01050RD150mm²Red
YMz1Krvasdlwd-AL 8.7/15kVB1E15KV01070RD170mm²Red
YMz1Krvasdlwd-AL 8.7/15kVB1E15KV01095RD195mm²Red
YMz1Krvasdlwd-AL 8.7/15kVB1E15KV01120RD1120mm²Red
YMz1Krvasdlwd-AL 8.7/15kVB1E15KV01150RD1150mm²Red
YMz1Krvasdlwd-AL 8.7/15kVB1E15KV01185RD1185mm²Red
YMz1Krvasdlwd-AL 8.7/15kVB1E15KV01240RD1240mm²Red
YMz1Krvasdlwd-AL 8.7/15kVB1E15KV01300RD1300mm²Red
YMz1Krvasdlwd-AL 8.7/15kVB1E15KV01400RD1400mm²Red
YMz1Krvasdlwd-AL 8.7/15kVB1E15KV01500RD1500mm²Red
YMz1Krvasdlwd-AL 8.7/15kVB1E15KV01630RD1630mm²Red
YMz1Krvasdlwd-AL 8.7/15kVB1E15KV03050RD350mm²Red
YMz1Krvasdlwd-AL 8.7/15kVB1E15KV03070RD370mm²Red
YMz1Krvasdlwd-AL 8.7/15kVB1E15KV03095RD395mm²Red
YMz1Krvasdlwd-AL 8.7/15kVB1E15KV03120RD3120mm²Red
YMz1Krvasdlwd-AL 8.7/15kVB1E15KV03150RD3150mm²Red
YMz1Krvasdlwd-AL 8.7/15kVB1E15KV03185RD3185mm²Red
YMz1Krvasdlwd-AL 8.7/15kVB1E15KV03240RD3240mm²Red
YMz1Krvasdlwd-AL 8.7/15kVB1E15KV03300RD3300mm²Red
YMz1Krvasdlwd-AL 12/20kVB1E20KV01050RD150mm²Red
YMz1Krvasdlwd-AL 12/20kVB1E20KV01070RD170mm²Red
YMz1Krvasdlwd-AL 12/20kVB1E20KV01095RD195mm²Red
YMz1Krvasdlwd-AL 12/20kVB1E20KV01120RD1120mm²Red
YMz1Krvasdlwd-AL 12/20kVB1E20KV01150RD1150mm²Red
YMz1Krvasdlwd-AL 12/20kVB1E20KV01185RD1185mm²Red
YMz1Krvasdlwd-AL 12/20kVB1E20KV01240RD1240mm²Red
YMz1Krvasdlwd-AL 12/20kVB1E20KV01300RD1300mm²Red
YMz1Krvasdlwd-AL 12/20kVB1E20KV01400RD1400mm²Red
YMz1Krvasdlwd-AL 12/20kVB1E20KV01500RD1500mm²Red
YMz1Krvasdlwd-AL 12/20kVB1E20KV01630RD1630mm²Red
YMz1Krvasdlwd-AL 12/20kVB1E20KV03050RD350mm²Red
YMz1Krvasdlwd-AL 12/20kVB1E20KV03070RD370mm²Red
YMz1Krvasdlwd-AL 12/20kVB1E20KV03095RD395mm²Red
YMz1Krvasdlwd-AL 12/20kVB1E20KV03120RD3120mm²Red
YMz1Krvasdlwd-AL 12/20kVB1E20KV03150RD3150mm²Red
YMz1Krvasdlwd-AL 12/20kVB1E20KV03185RD3185mm²Red
YMz1Krvasdlwd-AL 12/20kVB1E20KV03240RD3240mm²Red
YMz1Krvasdlwd-AL 18/30kVB1E30KV01050RD150mm²Red
YMz1Krvasdlwd-AL 18/30kVB1E30KV01070RD170mm²Red
YMz1Krvasdlwd-AL 18/30kVB1E30KV01095RD195mm²Red
YMz1Krvasdlwd-AL 18/30kVB1E30KV01120RD1120mm²Red
YMz1Krvasdlwd-AL 18/30kVB1E30KV01150RD1150mm²Red
YMz1Krvasdlwd-AL 18/30kVB1E30KV01185RD1185mm²Red
YMz1Krvasdlwd-AL 18/30kVB1E30KV01240RD1240mm²Red
YMz1Krvasdlwd-AL 18/30kVB1E30KV01300RD1300mm²Red
YMz1Krvasdlwd-AL 18/30kVB1E30KV01400RD1400mm²Red
YMz1Krvasdlwd-AL 18/30kVB1E30KV01500RD1500mm²Red
YMz1Krvasdlwd-AL 18/30kVB1E30KV01630RD1630mm²Red
YMz1Krvasdlwd-AL 18/30kVB1E30KV03050RD350mm²Red
YMz1Krvasdlwd-AL 18/30kVB1E30KV03070RD370mm²Red
YMz1Krvasdlwd-AL 18/30kVB1E30KV03095RD395mm²Red
YMz1Krvasdlwd-AL 18/30kVB1E30KV03120RD3120mm²Red
YMz1Krvasdlwd-AL 18/30kVB1E30KV03150RD3150mm²Red